XT9 Technical data

Part. no 12-1350.

Laser detector XT9 can be used to measure Straightness, Bore Center and Values.

  1. On/Off.

  2. Bluetooth connection.

  3. Battery and charge indicator.

  4. Detector PSD.

NOTE! This device is a part of a measuring system and the intended use for the device is industrial measuring together with other Easy-Laser products, according to the instructions in this manual. The device is intended for professional use only. Neither Easy-Laser nor its authorized distri

SERVICE AND SUPPORT

If the unit is damaged it has to be sent for repair. Contact your local service center as found on www.easylaser.com.


Communication BT Wireless technology
Connections Charger
Type of battery Li-Ion chargeable
Operating time Up to 15 hours continuous use
Operating temperature -10–50 °C [14–122 °F]
Charging temperature (battery) 0–40 °C [32–104 °F]
Storage temperature -20–50 °C [-4–122 °F]
Relative humidity 10–95% non condensing
Housing materials Aluminum, PC/ABS
Dimensions 99.9 x Ø44 mm [3.933” x Ø1.732"]
Detector size 20x20 mm, 2 axis
Minimum measurable diameter 80 mm [3.15”] (se NOTE! below)
PSD accuracy at room temperature ±0.001 mm ±1%
PSD resolution 0.001 mm
PSD linearization Scale factor, offset and nonlinear compensation
PSD parallelism compensation Electrical
Inclinometer accuracy ±1°
Inclinometer resolution 0.1°
Inclinometer range 360°
Inclinometer linearization 7 parameters; model using A,B,C,D,E,F and offset.
Weight 194 g [6.8 oz]
Altitude 0-3000 m during storage/transport
  0-2000 m during operation

NOTE! When using the XT9 detector in long tubes with small diameters (<80 mm, 3.15"] wireless communication
can be affected. Always consult your distributor before purchase. For normal bore alignment applications there is no problem.

 

Switch batteries

If batteries need to be switched, contact your local service center.

Only use batteries provided by Easy-Laser.